based on block-container with overall dimensions 3x6x2,8 m

Equipment legend:
1 - cable entry openings for the cables of floor-mounted devices
|
4
|
2 - power socket for electric convection heating 220V
|
2
|
3 - power socket 220V
|
3
|
4 - power socket 36V
|
3
|
5 - built-in cupboard
|
2
|
6 - table
|
1
|
7 - semi-polstered chair
|
2
|
8 - power supply switchboard (cable entry)
|
1
|
9 - electric convection heater
|
4
|
10 - equipment location space
|
11 - Elterm wash stand with electrical water heater, pail
|
1
|
12 - shelf
|
1
|
13 - combined extract and input ventilation
|
2
|
14 - cable tray (shown by dotted line on the layout diagram)
|
|
15 - earth continuity metal conductor
|
1
|

Specifications:
heating system
|
electrical convection heaters
|
water supply system system
|
independent
|
sewage disposal
|
into receiving tank of Elterm wash stand
|
electrical fittings
|
distributing switchboard, emergency circuit breaker, electrical wiring laid in cable ducts
|
lighting
|
luminescent type
|
ventilation
|
natural draught and forced-draught ventilation
|
outside door
|
thermal insulant proofed metal door with lock
|
windows
|
PVC framed multiple glass pane
|
premises interior finish:
|
ceiling and walls
|
painted cement woodchip plates
|
floor
|
linoleum
|
exterior finish
|
polymer-coated galvanized shaped sheet
|
Back